Policy for The New Salon. Decide on an area this is certainly degree and structurally sound.

Policy for The New Salon. Decide on an area this is certainly degree and structurally sound.

Arrange For Your facebook date Salon

Install Pre-Delivery Flyer

Pre-Delivery Guide

CONGRATULATIONS!

Your Bullfrog Spas are going to be showing up quickly and can be an invaluable addition for you experience that is backyard living. Now you have actually opted for the perfect model, colors and JetPaks, there are only some more choices to be manufactured and things to consider.

WEB WEB SITE SELECTION

When selecting the area for the Bullfrog that is new Spa must look into the environment, your chosen lifestyle, and any privacy issues.

you might place your hot spa in order for it is possible to use the many optimal views of one’s home throughout every one of the periods. Arrange for any spa-side accessories you wish to include when determining how big the certain area you’ll want to for the spa. All the gear for the Bullfrog salon is situated behind an access panel right in front for the spa. The spa must not be placed against a wall surface or with create outs that could block access to this panel. Remember that following a relaxing soak and the amazing leisure provided by Bullfrog’s hydro-massage jets, an extended trek across your straight back garden may show to be only a little inconvenient, particularly within the dead of winter.

FOUNDATION

Your Bullfrog salon could be positioned on a deck, tangible pad, patio obstructs, pavers, pea gravel or crushed rock. Patios will routinely have a specific amount of fall to accommodate water run down nonetheless it shouldn’t go beyond 1” over a 8’ area. The entire root of the spa ought to be supported and should not be shimmed in the event that area may be out of degree. In the event that you intend to spot your spa on a deck, determine that the decks weight bearing load is adequate. In the event that deck is considerably elevated, unique factors should be made, including whether or not the distribution will need unique gear or extra manpower which could end in additional expense.

ACCESS FOR DELIVERY

Brown’s delivery team will bring your spa to your house employing a specifically created salon Dolly.

if they bring the spa on your home, the salon Dolly holds the spa in a straight place. According to the model, it’ll require 38” – 40” minimal clearance through gates, amongst the household and part fences, etc. 7’ – 10’ overhead clearance is likewise required. The dolly will not look at stones, holes, up or down stairs, over fences, up or down high hills, etc. All debris, fences, landscaping and obstacles that limit or block access should be removed to prepare for delivery.

When you have any queries or issues concerning the delivery or keeping of your Bullfrog salon, Brown’s will undoubtedly be thrilled to execute a site inspection that is complimentary. Please speak to your sales keep company with any concerns or even to schedule a house check out.

ELECTRIC NEEDS

Operating the wiring that is electrical the spa is the obligation unless it’s been contracted with us. We suggest that you utilize an electrician that is licensed. Brown’s is an authorized electric specialist and us to perform the wiring for your hot tub, please contact your sales associate if you would like. In case your wiring for the spa is certainly not to code, or the connections haven’t been made, the distribution crew will never be in a position to turn your spa on. The only connection the delivery crew will make is to the spa’s circuit board unless you have arranged for Brown’s master electrician to run the wiring.

A5L/R5L

A7/A7L & R7/R7L

A6/R6 & A6L/R6L

A8/A8D/A8L

The electric installing of your Bullfrog salon needs to be prior to nationwide and regional wiring rule.

All 240v 50amp spas must be wired utilizing no. 6 cables. a devoted, remote 50 amp GFCI breaker must be when you look at the line and positioned at the least 6’ through the spa. A “pig tail” needs to be connected to the GFCI breaker or disconnect of adequate size to achieve the spa’s access that is electrical with an extra 12’ to achieve the circuit board in the gear compartment. The length that is entire of cable must certanly be in conduit to satisfy rule. Each spa could have three access that is electrical. There is certainly one for each region of the spa plus one into the straight straight back. The diagrams about this page show the access points for each spa model while the chaseways by which the cable shall be given.

120V spas must certanly be connected to a dedicated 20amp GFCI protected circuit. No electrical cords works extremely well with this circuit.

GFCI WIRING DIAGRAM

THANK-YOU!

Many of us at Brown’s Pools & Spas appreciate the confidence and trust inside our business you’ve got demonstrated along with your purchase.

we have been sure that your Bullfrog that is new Spa provide you with, your friends and relations a long time of satisfaction.

The experienced staff at any one of our places can be acquired to help you. Our company is right right right here to present any details about the procedure and upkeep for the brand brand new hot spa so that as the best supply for almost any materials, add-ons, or solution you will need now or in the near future.